RF SPECIFICATIONS:
- Freq. Range = 700-3000 MHz
- Positive Gain Slope = 4 dB
- Gain range = 10 to 40 dB, Steps 0,5 dB
- Noise Figure = 7 dB
- Connectors = F, BNC, N or SMA
- Impedance = 75 or 50 Ohm
- RF INPUT Level Range = – 5 to – 50 dBm
- Damage Input Level = > + 10 dBm
- Input R.L. = 16 dB typ., 14 dB min.
- Output R.L. = 16 dB typ., 14 dB min.
- Output Frequency Responce = ± 1,5 dB Max
- Output Gain control = MGC or AGC selectable
RF MONITOR PORT (for each amplifier):
- On Front Panel -20 dB
- Connector = F or SMA
- Impedance = 75 or 50 Ω
- Flatness = ± 2 dB
LNB POWER CONTROL:
- D.C. VOLTAGE = OFF, 13V, 18V max 500 mA for each Input
- TONE = 22 KHz ON/OFF
- LNB Protections = short circuit and current limited
- LED = green = OK, red = dc short circuit Alarm
RF POWER SENSING ALARM:
- POWER THRESHOLD = adjust from -50 to -5 dBm
POWER SUPPLY (for each amplifier):
- 12 V d.c., 250 mA per module
GENERAL SPECIFICATIONS:
- SAFETY = EN 50 083-1 and EN 60 950.
- ENVIRONMENT:
– Temperature range: –30° / + 55° (max 60°)
– Umidity 95%
- EMC = EN 50 083-2