LPI-10

ROVER LNB POWERING INSERTER
5-3.000 MHz,
10 times individual switchable LNB Powering
(Voltage & Tone),
Redundant Hot-Swap PSU, Dry Contact Alarms

ROVER LPI-10-V-F
  • 5 – 3.000 MHz ultra wide band Operating Frequency Range
  • Up to 10 LNBS with indipendent Voltage Selection 13/18 V, 22 KHz
  • Up to 500 mA Current Consumption per path, with indipendent Short Circuit Protections & Alarms
  • Dual redundant Hot-Swap PSU with related LEDS & Dry Contacts Alarms

ROVER LPI-10-V-F-EN v5,3 l-2a

RF SPECIFICATIONS:

  • FREQ. RANGE = 5-3.000 MHz
  • CONNECTORS = F (f ) [BNC (f ) or SMA (f ) opt.]
  • IMPEDANCE = 75 Ohm (50 Ohm opt.)
  • RETURN LOSS IN/OUT = > 16 dB
  • INSERTION LOSS = 0,3 dB typ (0,8 dB@34 Hz)
  • MAX. POWER INPUT = + 30 dBm
  • FLATNESS IN 36 MHz WINDOW = < 0,3 dB
  • ISOLATION BETWEEN ADJACENT PATHS = > 85 dB

LNB POWER CONTROL:

  • D.C. VOLTAGE = OFF, 13V, 18V (or 24 optional)
  • 22 KHz TONE = ON/OFF
  • MAX Current for each Input = 500 mA
  • MAX Overall Current = 5 A (10 opt.)
  • LED green = OK, red = DC short circuit (Alarm)
  • LED ALARM INDICATION = Via Dry Contact

DRY CONTACT ALARM:

  • CONNECTOR = SUB-D9 Male
  • CONTACT LOAD = 65 V – 400 mA
  • A & B MAINS PSU = one defective or both
  • DC Short Circuit = at LNB Input

DUAL REDUNDANT HOT SWAP PSU:

  • N. 2 AC MAINS PSU = 110-240 VAC (with 2 separate Receptacles for 2 separate Power lines)
  • AC POWER CONSUMPTION = 60 VA

GENERAL SPECIFICATIONS:

  • SLIM CASE = 19” 1U Rack (35 cm depth)
  • NET WEIGHT = 4,8 Kg
  • SAFETY = EN 50 083-1 and EN 60 950.
  • ENVIRONMENTAL CONDITIONS:
    – Temperature range: –40° / + 55° (max 70°)
    – Umidity 95%
  • EMC = EN 50 083-2

ROVER LPI-10-V-F-EN ordering code definition v5,3 l-2

Download